reverend horton heat
reverend horton heat
A convenient, precise and powerful tool for HVAC&R engineers. This psychrometric chart use ASHRAE equations at normal temperature and pressure region and is perfectly consistent with all ASHRAE charts of No.1~7(SI Units) and No.1~5(IP Units).
Full functional trial, free upgrade.
Both Metric(SI) and English(IP) units support.
Save and load data function for each data input grid, all input data can be saved for loading next time program started.
Psychrometric chart
1. Use IAPWS-IF97 equation for water/vapor properties calculating, and treat moist air as real gas for high precision;
2. Dry bulb temperature and humidity ratio axis range can be changed easily, the chart generation is automatic and fast;
3. Draw protractor for enthalpy-humidity and sensible-total heat ratio;
4. Mouse point catch, snap and calculation, output point information and many air properties;
5. Normal and eastern(China) style support;
6. Chart grid snap, aided constant parameter lines across cursor point, middle button pan and mouse wheel zoom for convenient chart operating;
7. Many process point managements, include point pick up, data input grid, point definition select, point add, insert, reduce, delete, move up and down, open and save point list;
8. Convenient interface for process and mix point calculating;
9. Once and twice recycle calculating;
10. Point state convert calculating, and give warning and error message, output point information if point state is OK;
11. Chart plot/display setup and management support;
12. Chart can be easily printed, copied to clipboard as bmp and wmf format, and exported as bmp, jpg, wmf or emf format.
Duct Calculator
1. Calculate air/liquid and round/rectangle cross section duct;
2. Calculate duct flow resistance, environmental heat exchange, and adiabatic effect.
Note: Outer coefficient of heat transfer usually 3~10, >10 when winds.
Requirements: 200MHz CPU, 64M RAM,10M free disk space
Whats new in this version: Updated for high precision. New coordinate system; Add ASHRAE equation and real gas effect calculation; Water property updated to IAPWS-IF97 equation; Grid snap support.
Heat Transfer 3.00 offers you a great solution which can help you to solve Heat Transfer BVP, IVP, IP problems. Source code + Output files are included. Calculus (level) Programming makes solving partial differential equations, ordinary differential equations and algebraic equations simple. You state the equations, initial conditions, & parameter values and leave the solving method to the compiler. Equations maybe nonLinear, implicit, any order, any degree and/or constrained.
Major features
- Automatic Differentiation coupled with Operator Overloading are the key ingredience for a Calculus-level programming language.
- Our website introduces Calculus Programming. Our main point is simulating entire company processes, distribution systems, etc. with an eye on ones company goal.
- This is accomplished by nesting of simulation problems in one Complete simulation run.
Improvements of this version: Major changes ... examples now include BVP, IVP, & IP on heat transfer. Examples use Method of Lines for solving PDEs.
Requirements: Windows + VB6 RunTime files
Heat Transfer 3.00 is a simple and useful tool which allows you to solve Heat Transfer BVP, IVP, IP problems. Source code + Output files are included. Calculus (level) Programming makes solving partial differential equations, ordinary differential equations and algebraic equations simple.
You state the equations, initial conditions, & parameter values and leave the solving method to the compiler. Equations maybe nonLinear, implicit, any order, any degree and/or constrained.
Automatic Differentiation coupled with Operator Overloading are the key ingredience for a Calculus-level programming language.
- Examples now include BVP, IVP, & IP on heat transfer.
- Examples use Method of Lines for solving PDEs.
- Windows
- VB6 RunTime files
For a given input and output conditions Shell-and-Tube Heat Exchanger can estimate preliminary heat exchanger design parameters.
Here are some key features of "Shell and Tube Heat Exchanger":
1) heat exchange between counterflow fluids
2) no evaporation and no condensation
Shell-and-Tube Heat Exchanger - is a user friendly program which for a given heat exchanger initial conditions and geometry predicts outlet temperatures of both shell-side and tube-side fluids, heat exchanged, pressure drop on the tube sides and fluid velocity in the inlet/outlet nozzles.
For a given input and output conditions the program can estimate preliminary heat exchanger design parameters.
Program assumes:
heat exchange between counterflow fluids
shell insulation
heat transfer with ambient air.
shell side fluid heating is possible
evaporation and condensation are not considered
No mattter if you are a home owner or an apartment renter, you will be able to save some money on your heat bill by following some of the advice and tips in this eBook.
Sammy Sosa High Heat Baseball 2001 demo offers you a professional game with many rich benefits. The 2000 edition of High Heat Baseball shot out of left field last year to walk away with plenty of Editor's Choice and sports game of the year awards. Now, a winning tradition is being established with the introduction of Sammy Sosa High Heat Baseball 2001 edition!
High Heat 2001 includes the same famous true-to-life base running, fielding and managing, all the 3D modeled modern stadiums - along with several that no longer exist, as well as play-by-play announcement with Giants announcer Ted Robinson. And brand new to this edition are true face maps of every player in the MLB, proportional player models, 3D mounds - and even night games! Feel the 2001 heat!
Here are some key features of "Shell and Tube Heat Exchanger Design":
Step by step calculation
Estimate the Physical properties of more than 1450 components; the database has the ability to estimate Thermal Conductivity, Density, Heat Capacity and Viscosity. The database also included critical properties, boiling and melting points.
Estimate mixture properties. (ALL ESTIMATION METHODS CURRENTLY SUPPORT LIQUIDS ONLY)
Integrated customised database functions to allow user to add/delete compnents.
Ability to import properties to Shell/Tube sides form Microsoft Excel
Export Results summary to Microsoft Excel
Ability to calculate unknown shell or tube side temperatures by iteration method (solving by trial and error)
Also can select from different correlations to calculate shell or tube heat transfer coefficient
Calculate the scale resistance (dirt factor)
Shell/Tube side Reynolds and Nusselt numbers
Buffle spacing
Recommended minimun shell thickness, minimum recommended number and diameter of rods.
Calculate Shell/Nozzle/Channel/Head/Tubesheet Thickness.
Support S.I Units and English (U.S) Units of mesurement.
Duty Calculation
Overall heat transfer coefficient
Shell/Tube velocities.
Save/Load results.
Generate/Print a summary of results
Momentous Heat and Mass Transfer Calculator.Scientific Evaluator - Superlative collection of Operators and instant reference to recent calculations. Memory functions etc. A must have for Engineering professionals and students. This PocketPC software program empowers you with instant references and solutions of frequently encountered calculation at your finger tips. Just few taps, and all the calculations that consumed lots of efforts and time will vanish, there by increasing efficiency. This means you will have more time to analyze your information and make better informed decisions, thus helping professionals maintain a competitive edge and helping students to excel in their academics.Entropy Exchange in HeatXfer,Heat Conduction in Hollow Cylinder,Gray-body Radiation,Heat conduction in hollow sphere,Convection-Conduction Network,Critical Radius of Insulation,Black Body Radiation,Contact Heat Xfer Coeff,Film Temperature,Local FlatPlate Nusselt # (laminar),Avg FlatPlate Nusselt # (laminar),Tube Flow Nusselt # (turbulent),Nusselt # for cylinder in cross-flow,Heat conduction in plane wall,Heat convection,Single-lump transient temperature evolution.
Requirements: Windows Mobile for PocketPC 2000,2002&2003
Whats new in this version: Program now available for PocketPC 2003 loaded devices. New Scientific Evaluator. New Property Tables and more
Momentous Heat and Mass Transfer Calculator.Scientific Evaluator - Superlative collection of Operators and instant reference to recent calculations. Memory functions etc.A must have for Engineering professionals and students. This Palm software program empowers you with instant references and solutions of frequently encountered calculation at your finger tips. Just few taps, and all the calculations that consumed lots of efforts and time will vanish, there by increasing efficiency. This means you will have more time to analyze your information and make better informed decisions, thus helping professionals maintain a competitive edge and helping students to excel in their academics.Entropy Exchange in HeatXfer,Heat Conduction in Hollow Cylinder,Gray-body Radiation,Heat conduction in hollow sphere,Convection-Conduction Network,Critical Radius of Insulation,Black Body Radiation,Contact Heat Xfer Coeff,Film Temperature,Local FlatPlate Nusselt # (laminar),Avg FlatPlate Nusselt # (laminar),Tube Flow Nusselt # (turbulent),Nusselt # for cylinder in cross-flow,Heat conduction in plane wall,Heat convection,Single-lump transient temperature evolution.
Requirements: PalmOS 3.0 to 5.x
Whats new in this version: Program now available for New Scientific Evaluator. New Property Tables and more
+Step by step calculation
+Support S.I Units and English (U.S) Units of mesurement.
+User database functions to allow user to add/delete components and load to hot/cold side (Empty database!).
+Ability to import properties to Hot/Cold sides from Microsoft Excel.
+Ability to calculate unknown Cold or Hot side temperatures.
+Perform thermal analysis for bare tube double pipe (hairpin) heat exchangers.+Perform thermal analysis for finned tube double pipe (hairpin) heat exchangers.
+Choose from Counter Current or Co-Current Flow arrangement.
+Choose from Series arrangement or Series-Parallel arrangement.
+The software will also tell you the location of Hot/Cold fluids within the heat exchanger (Inner Pipe or Outer Pipe).
+Select from different correlations to calculate Cold/Hot side heat transfer coefficient. Also the ability to adjust Nusselt number if you do have a different correlation.
+Calculate the Area, Flow area, Length, Log Mean Temperature Differance, Number of Hairpins,Unknown Flow rate.
+Calculate the scale resistance (dirt factor), Equivalent Diameter.
+Calculate Pipe/Annulus side Reynolds, Nusselt numbers & Prandtl Numbers
+Duty Calculation, Clean and Design Overall heat transfer coefficient calculations.
+Pipe/Annulus velocities and Mass velocity calculations
+Number of Transfer Units and Thermal Capacity ratio calculation +Clean and Fouled Fin Efficiency calculations for finned tube heat exchanger.
+Pressure drop calculations & Entrance and Exit losses.
+Export Results summary to Microsoft Excel
+Save/Load results. Generate/Print a summary of results. For more information visit http://www.webbusterz.com or http://www.webbusterz.net
Want to place your software product here?
Please contact us for consideration.
Contact WareSeeker.com